{"id":1015,"date":"2025-10-29T12:14:57","date_gmt":"2025-10-29T12:14:57","guid":{"rendered":"https:\/\/megadiagnostic.com\/?post_type=product&#038;p=1015"},"modified":"2026-01-22T12:27:07","modified_gmt":"2026-01-22T12:27:07","slug":"moniteur-modulaire-ht8","status":"publish","type":"product","link":"https:\/\/megadiagnostic.com\/en\/product\/moniteur-modulaire-ht8\/","title":{"rendered":"Hwatime HT8 Modular Monitor"},"content":{"rendered":"<p data-start=\"860\" data-end=\"1358\">THE <strong data-start=\"863\" data-end=\"894\">HT8 Modular Patient Monitor<\/strong> of <strong data-start=\"898\" data-end=\"909\">Hwatime<\/strong> is a multiparameter monitoring medical device designed to guarantee the <strong data-start=\"993\" data-end=\"1037\">safety, precision and flexibility<\/strong> in all clinical environments. Compliant with safety requirements <strong data-start=\"1113\" data-end=\"1127\">IEC60601-1<\/strong>, <strong data-start=\"1129\" data-end=\"1145\">EN60601-2-27<\/strong> And <strong data-start=\"1149\" data-end=\"1165\">EN60601-2-30<\/strong>, He is protected against the effects of the <strong data-start=\"1206\" data-end=\"1224\">defibrillation<\/strong> and of the <strong data-start=\"1234\" data-end=\"1263\">electromedical surgery<\/strong>, ensuring display recovery in less than 10 seconds after a defibrillator shock.<\/p>\n<h4 data-start=\"1360\" data-end=\"1395\">\ud83d\udd39 <strong data-start=\"1368\" data-end=\"1395\">Main Functions:<\/strong><\/h4>\n<ul data-start=\"1396\" data-end=\"2203\">\n<li data-start=\"1396\" data-end=\"1771\">\n<p data-start=\"1398\" data-end=\"1475\"><strong data-start=\"1398\" data-end=\"1405\">ECG<\/strong> : 3 or 5 selectable leads (I, II, III, aVR, aVL, aVF, V)<\/p>\n<ul data-start=\"1478\" data-end=\"1771\">\n<li data-start=\"1478\" data-end=\"1515\">\n<p data-start=\"1480\" data-end=\"1515\">Calibration signal: 1 mV \u00b15 %<\/p>\n<\/li>\n<li data-start=\"1518\" data-end=\"1652\">\n<p data-start=\"1520\" data-end=\"1552\">Bandwidth depending on the mode:<\/p>\n<ul data-start=\"1557\" data-end=\"1652\">\n<li data-start=\"1557\" data-end=\"1587\">\n<p data-start=\"1559\" data-end=\"1587\">Diagnostic: 0.05 at 130 Hz<\/p>\n<\/li>\n<li data-start=\"1592\" data-end=\"1622\">\n<p data-start=\"1594\" data-end=\"1622\">Monitoring: 0.5 to 40 Hz<\/p>\n<\/li>\n<li data-start=\"1627\" data-end=\"1652\">\n<p data-start=\"1629\" data-end=\"1652\">Surgery: 1 to 20 Hz<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"1655\" data-end=\"1695\">\n<p data-start=\"1657\" data-end=\"1695\">Adjustable gain: 250, 500, 1000, 2000<\/p>\n<\/li>\n<li data-start=\"1698\" data-end=\"1736\">\n<p data-start=\"1700\" data-end=\"1736\">ECG signal range: \u00b18 mV (Vp-p)<\/p>\n<\/li>\n<li data-start=\"1739\" data-end=\"1771\">\n<p data-start=\"1741\" data-end=\"1771\">Review function available<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"1773\" data-end=\"1929\">\n<p data-start=\"1775\" data-end=\"1787\"><strong data-start=\"1775\" data-end=\"1783\">SpO\u2082<\/strong> :<\/p>\n<ul data-start=\"1790\" data-end=\"1929\">\n<li data-start=\"1790\" data-end=\"1811\">\n<p data-start=\"1792\" data-end=\"1811\">Range: 0 to 100 %<\/p>\n<\/li>\n<li data-start=\"1814\" data-end=\"1834\">\n<p data-start=\"1816\" data-end=\"1834\">Resolution: 1 %<\/p>\n<\/li>\n<li data-start=\"1837\" data-end=\"1886\">\n<p data-start=\"1839\" data-end=\"1886\">Accuracy: \u00b12 % in the range of 70 % to 99 %<\/p>\n<\/li>\n<li data-start=\"1889\" data-end=\"1929\">\n<p data-start=\"1891\" data-end=\"1929\">Method: Dual-wavelength LED<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"1931\" data-end=\"2203\">\n<p data-start=\"1933\" data-end=\"1959\"><strong data-start=\"1933\" data-end=\"1955\">Breathing (RESP)<\/strong> :<\/p>\n<ul data-start=\"1962\" data-end=\"2203\">\n<li data-start=\"1962\" data-end=\"2011\">\n<p data-start=\"1964\" data-end=\"2011\">Method: Thoracic impedance between RA and LL<\/p>\n<\/li>\n<li data-start=\"2014\" data-end=\"2047\">\n<p data-start=\"2016\" data-end=\"2047\">Bandwidth: 0.1 to 2.5 Hz<\/p>\n<\/li>\n<li data-start=\"2050\" data-end=\"2153\">\n<p data-start=\"2052\" data-end=\"2078\">Respiratory rate:<\/p>\n<ul data-start=\"2083\" data-end=\"2153\">\n<li data-start=\"2083\" data-end=\"2108\">\n<p data-start=\"2085\" data-end=\"2108\">Adults: 7 to 120 bpm<\/p>\n<\/li>\n<li data-start=\"2113\" data-end=\"2153\">\n<p data-start=\"2115\" data-end=\"2153\">Children and newborns: 7 to 150 bpm<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"2156\" data-end=\"2178\">\n<p data-start=\"2158\" data-end=\"2178\">Resolution: 1 bpm<\/p>\n<\/li>\n<li data-start=\"2181\" data-end=\"2203\">\n<p data-start=\"2183\" data-end=\"2203\">Accuracy: \u00b12 bpm<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h4 data-start=\"2205\" data-end=\"2247\">\ud83d\udd39 <strong data-start=\"2213\" data-end=\"2247\">Electrical Specifications:<\/strong><\/h4>\n<ul data-start=\"2248\" data-end=\"2491\">\n<li data-start=\"2248\" data-end=\"2290\">\n<p data-start=\"2250\" data-end=\"2290\"><strong data-start=\"2250\" data-end=\"2266\">Food<\/strong> AC 110\u2013240 V, 50 Hz<\/p>\n<\/li>\n<li data-start=\"2291\" data-end=\"2325\">\n<p data-start=\"2293\" data-end=\"2325\"><strong data-start=\"2293\" data-end=\"2317\">Average consumption<\/strong> : 8 W<\/p>\n<\/li>\n<li data-start=\"2326\" data-end=\"2373\">\n<p data-start=\"2328\" data-end=\"2373\"><strong data-start=\"2328\" data-end=\"2340\">Battery<\/strong> : rechargeable sealed lithium<\/p>\n<\/li>\n<li data-start=\"2374\" data-end=\"2440\">\n<p data-start=\"2376\" data-end=\"2440\"><strong data-start=\"2376\" data-end=\"2389\">Autonomy<\/strong> : until <strong data-start=\"2400\" data-end=\"2412\">8 hours<\/strong> in continuous operation<\/p>\n<\/li>\n<li data-start=\"2441\" data-end=\"2491\">\n<p data-start=\"2443\" data-end=\"2491\"><strong data-start=\"2443\" data-end=\"2464\">Charging time<\/strong> : approximately <strong data-start=\"2475\" data-end=\"2489\">4.5 hours<\/strong><\/p>\n<\/li>\n<\/ul>\n<h4 data-start=\"2493\" data-end=\"2529\">\ud83d\udd39 <strong data-start=\"2501\" data-end=\"2529\">Safety and compliance:<\/strong><\/h4>\n<ul data-start=\"2530\" data-end=\"2727\">\n<li data-start=\"2530\" data-end=\"2586\">\n<p data-start=\"2532\" data-end=\"2586\">Protection against electromedical interference<\/p>\n<\/li>\n<li data-start=\"2587\" data-end=\"2652\">\n<p data-start=\"2589\" data-end=\"2652\">Floating inlets ensuring complete patient isolation<\/p>\n<\/li>\n<li data-start=\"2653\" data-end=\"2727\">\n<p data-start=\"2655\" data-end=\"2727\">Automatic display restoration after defibrillation (\u226410 s)<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"2729\" data-end=\"2922\">THE <strong data-start=\"2732\" data-end=\"2747\">Hwatime HT8<\/strong> It combines reliability, durability and ease of use, making it an ideal choice for <strong data-start=\"2841\" data-end=\"2919\">intensive care units, operating theaters and emergency units<\/strong>.<\/p>","protected":false},"excerpt":{"rendered":"<p>THE <strong data-start=\"269\" data-end=\"276\">HT8<\/strong> Hwatime&#039;s modular monitor is a state-of-the-art product that complies with international medical safety standards. <strong data-start=\"395\" data-end=\"409\">IEC60601-1<\/strong>, <strong data-start=\"411\" data-end=\"427\">EN60601-2-27<\/strong> And <strong data-start=\"431\" data-end=\"447\">EN60601-2-30<\/strong>.<br data-start=\"448\" data-end=\"451\" \/>Designed for reliable and accurate monitoring, it measures the\u2019<strong data-start=\"510\" data-end=\"544\">ECG, SpO\u2082 and respiration<\/strong> in adult, pediatric and newborn patients.<br data-start=\"595\" data-end=\"598\" \/>Thanks to its integrated lithium battery offering <strong data-start=\"643\" data-end=\"675\">up to 8 hours of battery life<\/strong>, It ensures continuous monitoring, even in the event of relocation or power interruption.<\/p>","protected":false},"featured_media":1016,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[51,49],"product_tag":[],"class_list":["post-1015","product","type-product","status-publish","has-post-thumbnail","product_cat-anesthesie-reanimation","product_cat-bloc-operatoire","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product\/1015","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/comments?post=1015"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/media\/1016"}],"wp:attachment":[{"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/media?parent=1015"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product_brand?post=1015"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product_cat?post=1015"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product_tag?post=1015"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}