{"id":1018,"date":"2025-10-29T12:36:45","date_gmt":"2025-10-29T12:36:45","guid":{"rendered":"https:\/\/megadiagnostic.com\/?post_type=product&#038;p=1018"},"modified":"2026-01-22T12:24:43","modified_gmt":"2026-01-22T12:24:43","slug":"moniteur-modulaire-ht9","status":"publish","type":"product","link":"https:\/\/megadiagnostic.com\/en\/product\/moniteur-modulaire-ht9\/","title":{"rendered":"Hwatime HT9 Modular Monitor"},"content":{"rendered":"<p data-start=\"848\" data-end=\"1217\">THE <strong data-start=\"851\" data-end=\"882\">HT9 Modular Patient Monitor<\/strong> of <strong data-start=\"886\" data-end=\"897\">Hwatime<\/strong> is an advanced modular monitor designed to provide comprehensive and customizable monitoring according to clinical needs. Patient compatible <strong data-start=\"1052\" data-end=\"1090\">adults, pediatrics and neonates<\/strong>, It combines precision, speed and flexibility thanks to its oscillometric technology and multiple optional modules.<\/p>\n<h4 data-start=\"1219\" data-end=\"1291\">\ud83d\udd39 <strong data-start=\"1227\" data-end=\"1289\">Non-invasive blood pressure measurement (NIBP)<\/strong><\/h4>\n<ul data-start=\"1292\" data-end=\"2033\">\n<li data-start=\"1292\" data-end=\"1349\">\n<p data-start=\"1294\" data-end=\"1349\"><strong data-start=\"1294\" data-end=\"1311\">Technology :<\/strong> oscillometric during inflation<\/p>\n<\/li>\n<li data-start=\"1350\" data-end=\"1447\">\n<p data-start=\"1352\" data-end=\"1375\"><strong data-start=\"1352\" data-end=\"1373\">Measurement range:<\/strong><\/p>\n<ul data-start=\"1378\" data-end=\"1447\">\n<li data-start=\"1378\" data-end=\"1416\">\n<p data-start=\"1380\" data-end=\"1416\">Adult\/Pediatric: 40\u2013240 mmHg<\/p>\n<\/li>\n<li data-start=\"1419\" data-end=\"1447\">\n<p data-start=\"1421\" data-end=\"1447\">Newborn: 40\u2013150 mmHg<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"1448\" data-end=\"1488\">\n<p data-start=\"1450\" data-end=\"1488\"><strong data-start=\"1450\" data-end=\"1479\">Typical measurement cycle:<\/strong> &lt; 40 s<\/p>\n<\/li>\n<li data-start=\"1489\" data-end=\"1587\">\n<p data-start=\"1491\" data-end=\"1587\"><strong data-start=\"1491\" data-end=\"1527\">Selectable cycle modes:<\/strong> 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480 min<\/p>\n<\/li>\n<li data-start=\"1588\" data-end=\"1642\">\n<p data-start=\"1590\" data-end=\"1642\"><strong data-start=\"1590\" data-end=\"1605\">STAT mode:<\/strong> continuous playback for 5 minutes<\/p>\n<\/li>\n<li data-start=\"1643\" data-end=\"1863\">\n<p data-start=\"1645\" data-end=\"1671\"><strong data-start=\"1645\" data-end=\"1669\">Specific beaches:<\/strong><\/p>\n<ul data-start=\"1674\" data-end=\"1863\">\n<li data-start=\"1674\" data-end=\"1732\">\n<p data-start=\"1676\" data-end=\"1732\">Adult: SYS 40\u2013270 \/ DIA 10\u2013215 \/ Mean 20\u2013165 mmHg<\/p>\n<\/li>\n<li data-start=\"1735\" data-end=\"1798\">\n<p data-start=\"1737\" data-end=\"1798\">Pediatric: SYS 40\u2013135 \/ DIA 10\u2013100 \/ Mean 20\u2013110 mmHg<\/p>\n<\/li>\n<li data-start=\"1801\" data-end=\"1863\">\n<p data-start=\"1803\" data-end=\"1863\">Newborn: SYS 40\u2013200 \/ DIA 10\u2013150 \/ Mean 20\u2013165 mmHg<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"1864\" data-end=\"1977\">\n<p data-start=\"1866\" data-end=\"1901\"><strong data-start=\"1866\" data-end=\"1899\">Maximum permissible pressure:<\/strong><\/p>\n<ul data-start=\"1904\" data-end=\"1977\">\n<li data-start=\"1904\" data-end=\"1925\">\n<p data-start=\"1906\" data-end=\"1925\">Adult: 300 mmHg<\/p>\n<\/li>\n<li data-start=\"1928\" data-end=\"1949\">\n<p data-start=\"1930\" data-end=\"1949\">Child: 240 mmHg<\/p>\n<\/li>\n<li data-start=\"1952\" data-end=\"1977\">\n<p data-start=\"1954\" data-end=\"1977\">Newborn: 150 mmHg<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"1978\" data-end=\"2005\">\n<p data-start=\"1980\" data-end=\"2005\"><strong data-start=\"1980\" data-end=\"1996\">Resolution :<\/strong> 1 mmHg<\/p>\n<\/li>\n<li data-start=\"2006\" data-end=\"2033\">\n<p data-start=\"2008\" data-end=\"2033\"><strong data-start=\"2008\" data-end=\"2023\">Precision :<\/strong> \u00b15 mmHg<\/p>\n<\/li>\n<\/ul>\n<h4 data-start=\"2035\" data-end=\"2058\">\ud83d\udd39 <strong data-start=\"2043\" data-end=\"2058\">Temperature<\/strong><\/h4>\n<ul data-start=\"2059\" data-end=\"2234\">\n<li data-start=\"2059\" data-end=\"2077\">\n<p data-start=\"2061\" data-end=\"2077\"><strong data-start=\"2061\" data-end=\"2073\">Channels:<\/strong> 2<\/p>\n<\/li>\n<li data-start=\"2078\" data-end=\"2111\">\n<p data-start=\"2080\" data-end=\"2111\"><strong data-start=\"2080\" data-end=\"2101\">Measurement range:<\/strong> 0\u201350 \u00b0C<\/p>\n<\/li>\n<li data-start=\"2112\" data-end=\"2139\">\n<p data-start=\"2114\" data-end=\"2139\"><strong data-start=\"2114\" data-end=\"2129\">Precision :<\/strong> \u00b10.1 \u00b0C<\/p>\n<\/li>\n<li data-start=\"2140\" data-end=\"2179\">\n<p data-start=\"2142\" data-end=\"2179\"><strong data-start=\"2142\" data-end=\"2170\">Display resolution:<\/strong> 0.1 \u00b0C<\/p>\n<\/li>\n<li data-start=\"2180\" data-end=\"2234\">\n<p data-start=\"2182\" data-end=\"2234\"><strong data-start=\"2182\" data-end=\"2206\">Compatible probes:<\/strong> YSI 400 and YSI 700 Series<\/p>\n<\/li>\n<\/ul>\n<h4 data-start=\"2236\" data-end=\"2279\">\ud83d\udd39 <strong data-start=\"2244\" data-end=\"2279\">Calculations and data storage<\/strong><\/h4>\n<ul data-start=\"2280\" data-end=\"2518\">\n<li data-start=\"2280\" data-end=\"2368\">\n<p data-start=\"2282\" data-end=\"2368\">Calculations available: dose, ventilation, renal function, hemodynamics, oxygenation<\/p>\n<\/li>\n<li data-start=\"2369\" data-end=\"2518\">\n<p data-start=\"2371\" data-end=\"2399\"><strong data-start=\"2371\" data-end=\"2397\">Storage capacity:<\/strong><\/p>\n<ul data-start=\"2402\" data-end=\"2518\">\n<li data-start=\"2402\" data-end=\"2426\">\n<p data-start=\"2404\" data-end=\"2426\">Data: 200 hours<\/p>\n<\/li>\n<li data-start=\"2429\" data-end=\"2457\">\n<p data-start=\"2431\" data-end=\"2457\">Alarm groups: 1000<\/p>\n<\/li>\n<li data-start=\"2460\" data-end=\"2492\">\n<p data-start=\"2462\" data-end=\"2492\">NIBP History: 720 hours<\/p>\n<\/li>\n<li data-start=\"2495\" data-end=\"2518\">\n<p data-start=\"2497\" data-end=\"2518\">Curves: 48 hours<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h4 data-start=\"2520\" data-end=\"2550\">\ud83d\udd39 <strong data-start=\"2528\" data-end=\"2550\">Optional modules<\/strong><\/h4>\n<ul data-start=\"2551\" data-end=\"2991\">\n<li data-start=\"2551\" data-end=\"2702\">\n<p data-start=\"2553\" data-end=\"2584\"><strong data-start=\"2553\" data-end=\"2582\">CO\u2082 (main \/ lateral)<\/strong><\/p>\n<ul data-start=\"2587\" data-end=\"2702\">\n<li data-start=\"2587\" data-end=\"2605\">\n<p data-start=\"2589\" data-end=\"2605\">Range: 0\u201315 %<\/p>\n<\/li>\n<li data-start=\"2608\" data-end=\"2631\">\n<p data-start=\"2610\" data-end=\"2631\">Resolution: 1 mmHg<\/p>\n<\/li>\n<li data-start=\"2634\" data-end=\"2661\">\n<p data-start=\"2636\" data-end=\"2661\">Accuracy: &lt; 50 ml\/min<\/p>\n<\/li>\n<li data-start=\"2664\" data-end=\"2702\">\n<p data-start=\"2666\" data-end=\"2702\">Respiratory rate: 2\u2013120 bpm<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"2704\" data-end=\"2991\">\n<p data-start=\"2706\" data-end=\"2746\"><strong data-start=\"2706\" data-end=\"2744\">IBP (invasive blood pressure)<\/strong><\/p>\n<ul data-start=\"2749\" data-end=\"2991\">\n<li data-start=\"2749\" data-end=\"2767\">\n<p data-start=\"2751\" data-end=\"2767\"><strong data-start=\"2751\" data-end=\"2763\">Channels:<\/strong> 2<\/p>\n<\/li>\n<li data-start=\"2770\" data-end=\"2805\">\n<p data-start=\"2772\" data-end=\"2805\"><strong data-start=\"2772\" data-end=\"2787\">Precision :<\/strong> \u00b12 % or \u00b11 mmHg<\/p>\n<\/li>\n<li data-start=\"2808\" data-end=\"2874\">\n<p data-start=\"2810\" data-end=\"2874\"><strong data-start=\"2810\" data-end=\"2836\">Measurable pressures:<\/strong> ART, PA, CVP, RAP, LAP, ICP, P1, P2<\/p>\n<\/li>\n<li data-start=\"2877\" data-end=\"2991\">\n<p data-start=\"2879\" data-end=\"2893\"><strong data-start=\"2879\" data-end=\"2891\">Beaches:<\/strong><\/p>\n<ul data-start=\"2898\" data-end=\"2991\">\n<li data-start=\"2898\" data-end=\"2920\">\n<p data-start=\"2900\" data-end=\"2920\">PA: -6 to 120 mmHg<\/p>\n<\/li>\n<li data-start=\"2925\" data-end=\"2960\">\n<p data-start=\"2927\" data-end=\"2960\">CVP\/RAP\/LAP\/ICP: -10 to 40 mmHg<\/p>\n<\/li>\n<li data-start=\"2965\" data-end=\"2991\">\n<p data-start=\"2967\" data-end=\"2991\">P1\/P2: -10 to 300 mmHg<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h4 data-start=\"2993\" data-end=\"3029\">\ud83d\udd39 <strong data-start=\"3001\" data-end=\"3029\">Recorder (optional)<\/strong><\/h4>\n<ul data-start=\"3030\" data-end=\"3165\">\n<li data-start=\"3030\" data-end=\"3071\">\n<p data-start=\"3032\" data-end=\"3071\"><strong data-start=\"3032\" data-end=\"3042\">Kind :<\/strong> 50mm thermal printer<\/p>\n<\/li>\n<li data-start=\"3072\" data-end=\"3109\">\n<p data-start=\"3074\" data-end=\"3109\"><strong data-start=\"3074\" data-end=\"3090\">Resolution :<\/strong> high definition<\/p>\n<\/li>\n<li data-start=\"3110\" data-end=\"3146\">\n<p data-start=\"3112\" data-end=\"3146\"><strong data-start=\"3112\" data-end=\"3125\">Speed :<\/strong> 25 mm\/s or 50 mm\/s<\/p>\n<\/li>\n<li data-start=\"3147\" data-end=\"3165\">\n<p data-start=\"3149\" data-end=\"3165\"><strong data-start=\"3149\" data-end=\"3161\">Channels:<\/strong> 3<\/p>\n<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>THE <strong data-start=\"312\" data-end=\"319\">HT9<\/strong> is a high-performance modular monitor designed for comprehensive and accurate monitoring of adult, pediatric, and neonatal patients. It integrates the <strong data-start=\"478\" data-end=\"485\">PNI<\/strong>, there <strong data-start=\"490\" data-end=\"505\">temperature<\/strong>, and offers optional modules <strong data-start=\"540\" data-end=\"547\">CO\u2082<\/strong> And <strong data-start=\"551\" data-end=\"558\">IBP<\/strong>. Thanks to its advanced oscillometric technology and rapid measurements (&lt;40 seconds), it delivers reliable and consistent results. Ideal for... <strong data-start=\"708\" data-end=\"778\">intensive care units, operating theaters and emergency units<\/strong>.<\/p>","protected":false},"featured_media":1019,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[51,49],"product_tag":[],"class_list":["post-1018","product","type-product","status-publish","has-post-thumbnail","product_cat-anesthesie-reanimation","product_cat-bloc-operatoire","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product\/1018","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/comments?post=1018"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/media\/1019"}],"wp:attachment":[{"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/media?parent=1018"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product_brand?post=1018"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product_cat?post=1018"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product_tag?post=1018"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}