{"id":1043,"date":"2025-10-30T13:05:01","date_gmt":"2025-10-30T13:05:01","guid":{"rendered":"https:\/\/megadiagnostic.com\/?post_type=product&#038;p=1043"},"modified":"2026-01-22T16:22:10","modified_gmt":"2026-01-22T16:22:10","slug":"crius-v6-respirateur-de-reanimation","status":"publish","type":"product","link":"https:\/\/megadiagnostic.com\/en\/product\/crius-v6-respirateur-de-reanimation\/","title":{"rendered":"CRIUS V6 Resuscitation Ventilator - NORTHERN"},"content":{"rendered":"<h3 data-start=\"729\" data-end=\"768\"><strong data-start=\"736\" data-end=\"768\">Main features<\/strong><\/h3>\n<ul data-start=\"770\" data-end=\"1623\">\n<li data-start=\"770\" data-end=\"846\">\n<p data-start=\"772\" data-end=\"846\"><strong data-start=\"772\" data-end=\"808\">15.6&quot; color TFT touchscreen\u2019<\/strong>, rotating 360\u00b0 (option: 5&#039;&#039; screen)<\/p>\n<\/li>\n<li data-start=\"847\" data-end=\"925\">\n<p data-start=\"849\" data-end=\"925\"><strong data-start=\"849\" data-end=\"874\">Turbine technology<\/strong> : operation without compressor or central gas<\/p>\n<\/li>\n<li data-start=\"926\" data-end=\"1001\">\n<p data-start=\"928\" data-end=\"1001\"><strong data-start=\"928\" data-end=\"968\">Invasive and non-invasive ventilation<\/strong> (adult, pediatric, neonatal)<\/p>\n<\/li>\n<li data-start=\"1002\" data-end=\"1071\">\n<p data-start=\"1004\" data-end=\"1071\"><strong data-start=\"1004\" data-end=\"1037\">Full electronic control<\/strong> (high-precision microprocessor)<\/p>\n<\/li>\n<li data-start=\"1072\" data-end=\"1142\">\n<p data-start=\"1074\" data-end=\"1142\"><strong data-start=\"1074\" data-end=\"1107\">Wide range of tidal volume<\/strong> : 5 \u2013 2000 ml (option 2 \u2013 2000 ml)<\/p>\n<\/li>\n<li data-start=\"1143\" data-end=\"1193\">\n<p data-start=\"1145\" data-end=\"1193\"><strong data-start=\"1145\" data-end=\"1175\">Low operating costs<\/strong>, reduced maintenance<\/p>\n<\/li>\n<li data-start=\"1194\" data-end=\"1263\">\n<p data-start=\"1196\" data-end=\"1263\"><strong data-start=\"1196\" data-end=\"1222\">Two lithium batteries<\/strong> offering up to <strong data-start=\"1239\" data-end=\"1263\">6 hours of battery life<\/strong><\/p>\n<\/li>\n<li data-start=\"1264\" data-end=\"1338\">\n<p data-start=\"1266\" data-end=\"1338\"><strong data-start=\"1266\" data-end=\"1305\">Integrated self-checking system<\/strong> (leaks, power supply, safety)<\/p>\n<\/li>\n<li data-start=\"1339\" data-end=\"1404\">\n<p data-start=\"1341\" data-end=\"1404\"><strong data-start=\"1341\" data-end=\"1380\">Automatic leak compensation<\/strong> for stable ventilation<\/p>\n<\/li>\n<li data-start=\"1405\" data-end=\"1448\">\n<p data-start=\"1407\" data-end=\"1448\"><strong data-start=\"1407\" data-end=\"1448\">Manual apnea setting: 0.1 \u2013 6 s<\/strong><\/p>\n<\/li>\n<li data-start=\"1449\" data-end=\"1514\">\n<p data-start=\"1451\" data-end=\"1514\"><strong data-start=\"1451\" data-end=\"1485\">EtCO\u2082 and SpO\u2082 dual interface<\/strong> (real-time monitoring)<\/p>\n<\/li>\n<li data-start=\"1515\" data-end=\"1562\">\n<p data-start=\"1517\" data-end=\"1562\"><strong data-start=\"1517\" data-end=\"1562\">High and low pressure oxygen connection<\/strong><\/p>\n<\/li>\n<li data-start=\"1563\" data-end=\"1623\">\n<p data-start=\"1565\" data-end=\"1623\"><strong data-start=\"1565\" data-end=\"1595\">Optional neonatal sensor<\/strong> for minimal volumes (2 ml)<\/p>\n<\/li>\n<\/ul>\n<h3 data-start=\"1630\" data-end=\"1661\"><strong data-start=\"1637\" data-end=\"1661\">Ventilation modes<\/strong><\/h3>\n<h4 data-start=\"1663\" data-end=\"1688\">Invasive ventilation<\/h4>\n<p data-start=\"1689\" data-end=\"1806\">VC-ACV, PC-ACV, PRVC, VC-SIMV, SIMV-PRVC, PC-Dual PAP, PC-APRV, CPAP\/PSV, CPAP\/VG, AMV\/MMV, NCPAP, apnea ventilation.<\/p>\n<h4 data-start=\"1808\" data-end=\"1837\">Non-invasive ventilation<\/h4>\n<p data-start=\"1838\" data-end=\"1926\">PC-ACV, PRVC, SIMV-PRVC, PC-Dual PAP, PC-APRV, NCPAP, CPAP\/PSV, CPAP\/VG, AMV\/MMV, apnea.<\/p>\n<h4 data-start=\"1928\" data-end=\"1961\">High-flow oxygen therapy<\/h4>\n<p data-start=\"1962\" data-end=\"2055\">Support for <strong data-start=\"1981\" data-end=\"2015\">High Flow Nasal Cannula (HFNC)<\/strong> for gentle and effective oxygenation.<\/p>\n<h3 data-start=\"2062\" data-end=\"2102\"><strong data-start=\"2069\" data-end=\"2102\">Built-in tools and functions<\/strong><\/h3>\n<p data-start=\"2103\" data-end=\"2262\">Rlung, RSBI, P0.1, PEEPi, V-CO\u2082, PTP, Expiratory Delay, ATC, PCVR, PPS, Compliance, Calibration, inhalation O\u2082, 100 % O\u2082, screen lock, safe shutdown.<\/p>\n<h3 data-start=\"2269\" data-end=\"2301\"><strong data-start=\"2276\" data-end=\"2301\">Interfaces and measurements<\/strong><\/h3>\n<ul data-start=\"2302\" data-end=\"2545\">\n<li data-start=\"2302\" data-end=\"2406\">\n<p data-start=\"2304\" data-end=\"2406\"><strong data-start=\"2304\" data-end=\"2313\">EtCO\u2082<\/strong> : displays the concentration of exhaled carbon dioxide, a key indicator of ventilation.<\/p>\n<\/li>\n<li data-start=\"2407\" data-end=\"2479\">\n<p data-start=\"2409\" data-end=\"2479\"><strong data-start=\"2409\" data-end=\"2417\">SpO\u2082<\/strong> : real-time measurement of blood oxygen saturation.<\/p>\n<\/li>\n<li data-start=\"2480\" data-end=\"2545\">\n<p data-start=\"2482\" data-end=\"2545\"><strong data-start=\"2482\" data-end=\"2512\">Dual simultaneous display<\/strong> for clear and secure tracking.<\/p>\n<\/li>\n<\/ul>\n<h3 data-start=\"2552\" data-end=\"2585\"><strong data-start=\"2559\" data-end=\"2585\">Clinical applications<\/strong><\/h3>\n<p data-start=\"2586\" data-end=\"2636\">The Crius V6 meets a wide range of requirements:<\/p>\n<ul data-start=\"2638\" data-end=\"2853\">\n<li data-start=\"2638\" data-end=\"2681\">\n<p data-start=\"2640\" data-end=\"2681\"><strong data-start=\"2640\" data-end=\"2681\">Intensive Care Units (ICU)<\/strong><\/p>\n<\/li>\n<li data-start=\"2682\" data-end=\"2713\">\n<p data-start=\"2684\" data-end=\"2713\"><strong data-start=\"2684\" data-end=\"2713\">Anesthesia and resuscitation<\/strong><\/p>\n<\/li>\n<li data-start=\"2714\" data-end=\"2744\">\n<p data-start=\"2716\" data-end=\"2744\"><strong data-start=\"2716\" data-end=\"2744\">Neonatal Intensive Care Units (NICU)<\/strong><\/p>\n<\/li>\n<li data-start=\"2745\" data-end=\"2769\">\n<p data-start=\"2747\" data-end=\"2769\"><strong data-start=\"2747\" data-end=\"2769\">Operating rooms<\/strong><\/p>\n<\/li>\n<li data-start=\"2770\" data-end=\"2808\">\n<p data-start=\"2772\" data-end=\"2808\"><strong data-start=\"2772\" data-end=\"2808\">Emergency services and ambulances<\/strong><\/p>\n<\/li>\n<li data-start=\"2809\" data-end=\"2853\">\n<p data-start=\"2811\" data-end=\"2853\"><strong data-start=\"2811\" data-end=\"2853\">Intra-hospital or extra-hospital transfers<\/strong><\/p>\n<\/li>\n<\/ul>\n<h3 data-start=\"2860\" data-end=\"2885\"><strong data-start=\"2867\" data-end=\"2885\">Key advantages<\/strong><\/h3>\n<ul data-start=\"2886\" data-end=\"3245\">\n<li data-start=\"2886\" data-end=\"2961\">\n<p data-start=\"2888\" data-end=\"2961\">Suitable for all patient profiles: <strong data-start=\"2928\" data-end=\"2961\">adult, pediatric, neonatal<\/strong><\/p>\n<\/li>\n<li data-start=\"2962\" data-end=\"3044\">\n<p data-start=\"2964\" data-end=\"3044\"><strong data-start=\"2964\" data-end=\"3017\">Intelligent, self-adapting ventilation system<\/strong> with volume\/pressure control<\/p>\n<\/li>\n<li data-start=\"3045\" data-end=\"3107\">\n<p data-start=\"3047\" data-end=\"3107\"><strong data-start=\"3047\" data-end=\"3084\">Stable and quiet ventilation<\/strong>, even without central gas<\/p>\n<\/li>\n<li data-start=\"3108\" data-end=\"3168\">\n<p data-start=\"3110\" data-end=\"3168\"><strong data-start=\"3110\" data-end=\"3168\">Simplified maintenance and reduced operating costs<\/strong><\/p>\n<\/li>\n<li data-start=\"3169\" data-end=\"3245\">\n<p data-start=\"3171\" data-end=\"3245\"><strong data-start=\"3171\" data-end=\"3199\">High clinical precision<\/strong> with multiple pulmonary assessment tools<\/p>\n<\/li>\n<\/ul>\n<h3 data-start=\"3252\" data-end=\"3279\"><strong data-start=\"3259\" data-end=\"3279\">Technical summary<\/strong><\/h3>\n<div class=\"_tableContainer_1rjym_1\">\n<div class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"3280\" data-end=\"3851\">\n<thead data-start=\"3280\" data-end=\"3315\">\n<tr data-start=\"3280\" data-end=\"3315\">\n<th data-start=\"3280\" data-end=\"3294\" data-col-size=\"sm\"><strong data-start=\"3282\" data-end=\"3293\">Element<\/strong><\/th>\n<th data-start=\"3294\" data-end=\"3315\" data-col-size=\"md\"><strong data-start=\"3296\" data-end=\"3313\">Specification<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"3352\" data-end=\"3851\">\n<tr data-start=\"3352\" data-end=\"3394\">\n<td data-start=\"3352\" data-end=\"3359\" data-col-size=\"sm\">Kind<\/td>\n<td data-start=\"3359\" data-end=\"3394\" data-col-size=\"md\">Mechanical turbine fan<\/td>\n<\/tr>\n<tr data-start=\"3395\" data-end=\"3437\">\n<td data-start=\"3395\" data-end=\"3403\" data-col-size=\"sm\">Screen<\/td>\n<td data-start=\"3403\" data-end=\"3437\" data-col-size=\"md\">15.6&quot; TFT touchscreen LCD, rotating<\/td>\n<\/tr>\n<tr data-start=\"3438\" data-end=\"3493\">\n<td data-start=\"3438\" data-end=\"3455\" data-col-size=\"sm\">Current volume<\/td>\n<td data-start=\"3455\" data-end=\"3493\" data-col-size=\"md\">5 \u2013 2000 ml (option: 2 \u2013 2000 ml)<\/td>\n<\/tr>\n<tr data-start=\"3494\" data-end=\"3534\">\n<td data-start=\"3494\" data-end=\"3502\" data-col-size=\"sm\">Fashions<\/td>\n<td data-start=\"3502\" data-end=\"3534\" data-col-size=\"md\">Invasive \/ Non-invasive \/ HFNC<\/td>\n<\/tr>\n<tr data-start=\"3535\" data-end=\"3597\">\n<td data-start=\"3535\" data-end=\"3550\" data-col-size=\"sm\">Food<\/td>\n<td data-start=\"3550\" data-end=\"3597\" data-col-size=\"md\">Mains power + 2 lithium batteries (up to 6 hours)<\/td>\n<\/tr>\n<tr data-start=\"3598\" data-end=\"3651\">\n<td data-start=\"3598\" data-end=\"3609\" data-col-size=\"sm\">Sensors<\/td>\n<td data-start=\"3609\" data-end=\"3651\" data-col-size=\"md\">SpO\u2082, EtCO\u2082, neonatal sensor (optional)<\/td>\n<\/tr>\n<tr data-start=\"3652\" data-end=\"3696\">\n<td data-start=\"3652\" data-end=\"3662\" data-col-size=\"sm\">Oxygen<\/td>\n<td data-start=\"3662\" data-end=\"3696\" data-col-size=\"md\">High and low pressure inlet<\/td>\n<\/tr>\n<tr data-start=\"3697\" data-end=\"3741\">\n<td data-start=\"3697\" data-end=\"3708\" data-col-size=\"sm\">Patients<\/td>\n<td data-start=\"3708\" data-end=\"3741\" data-col-size=\"md\">Adults, children, newborns<\/td>\n<\/tr>\n<tr data-start=\"3742\" data-end=\"3795\">\n<td data-start=\"3742\" data-end=\"3756\" data-col-size=\"sm\">Use<\/td>\n<td data-start=\"3756\" data-end=\"3795\" data-col-size=\"md\">ICU, operating room, transport, emergency, NICU<\/td>\n<\/tr>\n<tr data-start=\"3796\" data-end=\"3851\">\n<td data-start=\"3796\" data-end=\"3806\" data-col-size=\"sm\">System<\/td>\n<td data-start=\"3806\" data-end=\"3851\" data-col-size=\"md\">Self-check + leak compensation<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p data-start=\"282\" data-end=\"722\">The Resuscitation Ventilator <strong data-start=\"285\" data-end=\"297\">Crius V6<\/strong> of <strong data-start=\"301\" data-end=\"321\">Northern Meditec<\/strong> is a <strong data-start=\"329\" data-end=\"384\">high-quality electronic mechanical fan<\/strong>, designed to provide ventilation <strong data-start=\"420\" data-end=\"448\">invasive and non-invasive<\/strong> to <strong data-start=\"453\" data-end=\"488\">adults, children and newborns<\/strong>.<br data-start=\"489\" data-end=\"492\" \/>Thanks to its <strong data-start=\"503\" data-end=\"537\">integrated turbine technology<\/strong>, her <strong data-start=\"543\" data-end=\"570\">15.6&quot; touchscreen\u2019<\/strong> and its <strong data-start=\"578\" data-end=\"619\">intelligent self-adaptation system<\/strong>, The Crius V6 guarantees precise, safe and economical ventilation, suitable for any clinical environment.<\/p>\n<h3 data-start=\"729\" data-end=\"768\"><\/h3>","protected":false},"featured_media":1045,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[51],"product_tag":[],"class_list":["post-1043","product","type-product","status-publish","has-post-thumbnail","product_cat-anesthesie-reanimation","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product\/1043","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/comments?post=1043"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/media\/1045"}],"wp:attachment":[{"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/media?parent=1043"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product_brand?post=1043"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product_cat?post=1043"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product_tag?post=1043"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}