{"id":1256,"date":"2025-11-05T12:24:41","date_gmt":"2025-11-05T12:24:41","guid":{"rendered":"https:\/\/megadiagnostic.com\/?post_type=product&#038;p=1256"},"modified":"2026-01-22T16:49:44","modified_gmt":"2026-01-22T16:49:44","slug":"chauffe-sang-et-fluides-intraveineux-stationnaire-ampirmini","status":"publish","type":"product","link":"https:\/\/megadiagnostic.com\/en\/product\/chauffe-sang-et-fluides-intraveineux-stationnaire-ampirmini\/","title":{"rendered":"AMPIRmini Stationary Blood and Intravenous Fluid Warmer - TAHAT"},"content":{"rendered":"<p data-start=\"930\" data-end=\"1386\">L&#039;\u2019<strong data-start=\"932\" data-end=\"945\">AMPIRmini<\/strong> is a stationary device for heating fluids and blood, intended for the <strong data-start=\"1025\" data-end=\"1073\">prevention and treatment of hypothermia<\/strong> in adults and children, before, during and after surgical procedures.<br data-start=\"1157\" data-end=\"1160\" \/>Compact, reliable and easy to use, it is suitable for <strong data-start=\"1219\" data-end=\"1308\">hospital services, operating theaters, intensive care and resuscitation units<\/strong>, as well as the procedures of <strong data-start=\"1337\" data-end=\"1385\">Transfusion, infusion and enteral nutrition<\/strong>.<\/p>\n<p data-start=\"1388\" data-end=\"1441\">The system is composed of three main elements:<\/p>\n<ol data-start=\"1443\" data-end=\"2563\">\n<li data-start=\"1443\" data-end=\"1872\">\n<p data-start=\"1446\" data-end=\"1469\"><strong data-start=\"1446\" data-end=\"1467\">Control unit<\/strong><\/p>\n<ul data-start=\"1473\" data-end=\"1872\">\n<li data-start=\"1473\" data-end=\"1554\">\n<p data-start=\"1475\" data-end=\"1554\">Screen <strong data-start=\"1481\" data-end=\"1488\">LED<\/strong> displaying the current temperature and the programmed temperature.<\/p>\n<\/li>\n<li data-start=\"1558\" data-end=\"1735\">\n<p data-start=\"1560\" data-end=\"1596\"><strong data-start=\"1560\" data-end=\"1592\">Two operating modes<\/strong> :<\/p>\n<ul data-start=\"1602\" data-end=\"1735\">\n<li data-start=\"1602\" data-end=\"1677\">\n<p data-start=\"1604\" data-end=\"1677\"><em data-start=\"1604\" data-end=\"1617\">Manual mode<\/em> : precise adjustment from 34\u00b0C to 42\u00b0C, in increments of 0.1\u00b0C.<\/p>\n<\/li>\n<li data-start=\"1683\" data-end=\"1735\">\n<p data-start=\"1685\" data-end=\"1735\"><em data-start=\"1685\" data-end=\"1703\">Automatic mode<\/em> : constant maintenance at 36.6\u00b0C.<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"1739\" data-end=\"1872\">\n<p data-start=\"1741\" data-end=\"1872\"><strong data-start=\"1741\" data-end=\"1773\">Audible and visual alarms<\/strong> And <strong data-start=\"1777\" data-end=\"1795\">self-diagnosis<\/strong> automatic at startup and during use for optimal safety.<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"1874\" data-end=\"2359\">\n<p data-start=\"1877\" data-end=\"1910\"><strong data-start=\"1877\" data-end=\"1908\">Integrated heat exchanger<\/strong><\/p>\n<ul data-start=\"1914\" data-end=\"2359\">\n<li data-start=\"1914\" data-end=\"2023\">\n<p data-start=\"1916\" data-end=\"2023\"><strong data-start=\"1916\" data-end=\"1934\">Open system<\/strong>, compatible with all <strong data-start=\"1963\" data-end=\"1985\">Standard IV lines<\/strong> (including pediatric options).<\/p>\n<\/li>\n<li data-start=\"2027\" data-end=\"2164\">\n<p data-start=\"2029\" data-end=\"2164\">Possibility of placing the heat exchanger <strong data-start=\"2063\" data-end=\"2096\">very close to the injection site<\/strong>, reducing heat loss between the device and the patient.<\/p>\n<\/li>\n<li data-start=\"2168\" data-end=\"2202\">\n<p data-start=\"2170\" data-end=\"2202\"><strong data-start=\"2170\" data-end=\"2187\">Maximum flow rate<\/strong> : 2000 ml\/h.<\/p>\n<\/li>\n<li data-start=\"2206\" data-end=\"2359\">\n<p data-start=\"2208\" data-end=\"2359\"><strong data-start=\"2208\" data-end=\"2242\">Duralumin hot plate<\/strong> offering <strong data-start=\"2255\" data-end=\"2292\">excellent thermal conductivity<\/strong>, a large <strong data-start=\"2305\" data-end=\"2319\">sustainability<\/strong> and one <strong data-start=\"2327\" data-end=\"2358\">high mechanical resistance<\/strong>.<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"2361\" data-end=\"2563\">\n<p data-start=\"2364\" data-end=\"2400\"><strong data-start=\"2364\" data-end=\"2398\">Multipurpose fastening strap<\/strong><\/p>\n<ul data-start=\"2404\" data-end=\"2563\">\n<li data-start=\"2404\" data-end=\"2563\">\n<p data-start=\"2406\" data-end=\"2563\">Allows you to position the device <strong data-start=\"2442\" data-end=\"2469\">as close as possible to the patient<\/strong> : on a <strong data-start=\"2479\" data-end=\"2499\">IV stand<\/strong>, A <strong data-start=\"2504\" data-end=\"2511\">bed<\/strong>, a <strong data-start=\"2517\" data-end=\"2528\">litter<\/strong> or a <strong data-start=\"2536\" data-end=\"2560\">intervention table<\/strong>.<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<p data-start=\"2565\" data-end=\"2840\">Thanks to its robust design and its <strong data-start=\"2603\" data-end=\"2640\">thermal stability over 24 hours<\/strong>, L&#039;\u2019<strong data-start=\"2644\" data-end=\"2670\">AMPIRmini stationary<\/strong> guarantees a <strong data-start=\"2684\" data-end=\"2722\">constant and safe temperature<\/strong> medical fluids, thus improving the <strong data-start=\"2765\" data-end=\"2802\">patient safety and comfort<\/strong> in all clinical situations.<\/p>","protected":false},"excerpt":{"rendered":"<p data-start=\"265\" data-end=\"818\">L&#039;\u2019<strong data-start=\"267\" data-end=\"293\">AMPIRmini stationary<\/strong> is a compact device designed for <strong data-start=\"331\" data-end=\"379\">heating fluids and intravenous blood<\/strong> in order to <strong data-start=\"388\" data-end=\"425\">preventing and treating hypothermia<\/strong> during the phases <strong data-start=\"444\" data-end=\"477\">pre-, per- and post-operative<\/strong>.<br data-start=\"478\" data-end=\"481\" \/>His system <strong data-start=\"493\" data-end=\"503\">open<\/strong> allows the use <strong data-start=\"522\" data-end=\"555\">all standard IV lines<\/strong>, including pediatric.<br data-start=\"580\" data-end=\"583\" \/>Easy to install and secure, it ensures a <strong data-start=\"628\" data-end=\"664\">stable temperature over 24 hours<\/strong>, with <strong data-start=\"671\" data-end=\"702\">manual and automatic modes<\/strong>, <strong data-start=\"704\" data-end=\"736\">visual and audible alarms<\/strong>, And <strong data-start=\"741\" data-end=\"785\">high conductivity heat exchanger<\/strong> for fast and safe heating.<\/p>","protected":false},"featured_media":1257,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[49],"product_tag":[],"class_list":["post-1256","product","type-product","status-publish","has-post-thumbnail","product_cat-bloc-operatoire","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product\/1256","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/comments?post=1256"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/media\/1257"}],"wp:attachment":[{"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/media?parent=1256"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product_brand?post=1256"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product_cat?post=1256"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product_tag?post=1256"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}