{"id":1258,"date":"2025-11-05T12:48:42","date_gmt":"2025-11-05T12:48:42","guid":{"rendered":"https:\/\/megadiagnostic.com\/?post_type=product&#038;p=1258"},"modified":"2026-01-22T16:49:50","modified_gmt":"2026-01-22T16:49:50","slug":"systeme-de-rechauffement-de-fluides-et-de-sang-ampirmini-avec-echangeurs-externes","status":"publish","type":"product","link":"https:\/\/megadiagnostic.com\/en\/product\/systeme-de-rechauffement-de-fluides-et-de-sang-ampirmini-avec-echangeurs-externes\/","title":{"rendered":"AMPIRmini Fluid and Blood Warming System \u2013 with external exchangers _ TAHAT"},"content":{"rendered":"<p data-start=\"1034\" data-end=\"1416\">THE <strong data-start=\"1037\" data-end=\"1058\">AMPIRmini system<\/strong> is designed for the <strong data-start=\"1077\" data-end=\"1179\">Continuous warming of intravenous fluids, infusion solutions, blood and blood substitutes<\/strong>, as well as nutritional solutions.<br data-start=\"1216\" data-end=\"1219\" \/>It is primarily used in the <strong data-start=\"1258\" data-end=\"1279\">operating rooms<\/strong> and the <strong data-start=\"1287\" data-end=\"1316\">intensive care units<\/strong> For <strong data-start=\"1322\" data-end=\"1359\">preventing and treating hypothermia<\/strong> throughout the pre-, per- and post-operative phases.<\/p>\n<p data-start=\"1418\" data-end=\"1897\">This device combines <strong data-start=\"1440\" data-end=\"1491\">performance, safety and ease of use<\/strong>. It includes a <strong data-start=\"1509\" data-end=\"1540\">intuitive control unit<\/strong> with <strong data-start=\"1546\" data-end=\"1559\">LED screen<\/strong>, allowing precise temperature control in mode <strong data-start=\"1616\" data-end=\"1626\">manual<\/strong> (34\u00b0C to 42\u00b0C, in increments of 0.1\u00b0C) or <strong data-start=\"1662\" data-end=\"1677\">automatic<\/strong> (maintained at 36.6\u00b0C).<br data-start=\"1698\" data-end=\"1701\" \/>The system incorporates <strong data-start=\"1724\" data-end=\"1756\">audible and visual alarms<\/strong> as well as a <strong data-start=\"1769\" data-end=\"1800\">automatic self-diagnosis<\/strong> at startup and during operation, ensuring optimal safety for the patient.<\/p>\n<p data-start=\"1899\" data-end=\"2320\">THE <strong data-start=\"1903\" data-end=\"1942\">two external heat exchangers<\/strong> ensure excellent conductivity thanks to their <strong data-start=\"1993\" data-end=\"2027\">duralumin hot plate<\/strong>, Resistant and durable. Their open design allows the use of <strong data-start=\"2100\" data-end=\"2133\">all standard IV lines<\/strong>, including pediatric, with a <strong data-start=\"2167\" data-end=\"2198\">maximum flow rate of 2000 ml\/h<\/strong>.<br data-start=\"2199\" data-end=\"2202\" \/>Installed close to the injection site, they minimize heat loss and improve patient comfort.<\/p>\n<p data-start=\"2322\" data-end=\"2712\">The system can be <strong data-start=\"2343\" data-end=\"2398\">easily mounted on an IV stand or rail<\/strong> (diameter 15 to 55 mm) thanks to a <strong data-start=\"2432\" data-end=\"2465\">secure non-slip support<\/strong>.<br data-start=\"2466\" data-end=\"2469\" \/>The AMPIRmini allows for maintaining fluid temperature 24\/7, thus contributing to a <strong data-start=\"2560\" data-end=\"2591\">better thermal management<\/strong>, a <strong data-start=\"2597\" data-end=\"2644\">reduction of postoperative complications<\/strong> and one <strong data-start=\"2652\" data-end=\"2711\">overall improvement in patient care<\/strong>.<\/p>","protected":false},"excerpt":{"rendered":"<p data-start=\"281\" data-end=\"898\">THE <strong data-start=\"284\" data-end=\"305\">AMPIRmini system<\/strong> assures the <strong data-start=\"316\" data-end=\"418\">Continuous warming of intravenous fluids, infusion solutions, blood and blood substitutes<\/strong> for the <strong data-start=\"427\" data-end=\"475\">prevention and treatment of hypothermia<\/strong> at all perioperative stages.<br data-start=\"512\" data-end=\"515\" \/>Thanks to its <strong data-start=\"527\" data-end=\"561\">external heat exchangers<\/strong>, compatible with <strong data-start=\"580\" data-end=\"613\">all standard IV lines<\/strong>, It offers fast and even heating, adjustable manually or automatically.<br data-start=\"698\" data-end=\"701\" \/>Her <strong data-start=\"705\" data-end=\"718\">LED screen<\/strong>, his <strong data-start=\"724\" data-end=\"756\">audible and visual alarms<\/strong>, as well as its <strong data-start=\"772\" data-end=\"791\">self-diagnosis<\/strong> guarantee safe and precise use, both in <strong data-start=\"852\" data-end=\"871\">operating room<\/strong> than <strong data-start=\"878\" data-end=\"897\">intensive care<\/strong>.<\/p>","protected":false},"featured_media":1260,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[49],"product_tag":[],"class_list":["post-1258","product","type-product","status-publish","has-post-thumbnail","product_cat-bloc-operatoire","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product\/1258","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/comments?post=1258"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/media\/1260"}],"wp:attachment":[{"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/media?parent=1258"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product_brand?post=1258"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product_cat?post=1258"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product_tag?post=1258"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}