{"id":354,"date":"2025-07-23T17:32:49","date_gmt":"2025-07-23T17:32:49","guid":{"rendered":"https:\/\/megadiagnostic.com\/?post_type=product&#038;p=354"},"modified":"2025-11-12T09:08:23","modified_gmt":"2025-11-12T09:08:23","slug":"analyseur-des-electrolytes","status":"publish","type":"product","link":"https:\/\/megadiagnostic.com\/en\/product\/analyseur-des-electrolytes\/","title":{"rendered":"i-Smart 30 pro Electrolyte Analyzer"},"content":{"rendered":"<h3 data-start=\"120\" data-end=\"142\"><strong data-start=\"124\" data-end=\"142\">Specifications<\/strong><\/h3>\n<h4 data-start=\"144\" data-end=\"181\"><strong data-start=\"149\" data-end=\"181\">Operating parameters<\/strong><\/h4>\n<table style=\"height: 347px;\" width=\"966\">\n<thead>\n<tr>\n<th><strong>Measurement range (Blood)<\/strong><\/th>\n<th><strong>Sample type<\/strong><\/th>\n<th><strong>Measurement temperature<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Na\u207a: 20\u2013250 mmol\/L<\/td>\n<td>Whole blood, plasma, serum, urine<\/td>\n<td>37.0 \u00b1 0.2 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>K\u207a: 0.5\u201320.0 mmol\/L<\/td>\n<td><strong>Sample volume<\/strong><\/td>\n<td><strong>Measurement method<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Cl\u207b: 20\u2013250 mmol\/L<\/td>\n<td>60 \u00b5L<\/td>\n<td>Electrochemistry (direct ISE)<\/td>\n<\/tr>\n<tr>\n<td>Ca\u00b2\u207a: 0.25\u20135.0 mmol\/L<\/td>\n<td><strong>Sample introduction<\/strong><\/td>\n<td><strong>Calibration<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Measurement range (Urine)<\/strong><\/td>\n<td>Aspiration<\/td>\n<td>Automatic calibration in 1 or 2 points<\/p>\n<p>Manual calibration available if needed<\/td>\n<\/tr>\n<tr>\n<td>Na\u207a: 10\u2013400 mmol\/L<\/td>\n<td><strong>Sample container<\/strong><\/td>\n<td><strong>Temperature \/ Relative Humidity<\/strong><\/td>\n<\/tr>\n<tr>\n<td>K\u207a: 1.0\u2013120.0 mmol\/L<\/td>\n<td>Tube, syringe, capillary<\/td>\n<td>15\u201335 \u00b0C \/ 5\u201385 %<\/td>\n<\/tr>\n<tr>\n<td>Cl\u207b: 10\u2013400 mmol\/L<\/td>\n<td><strong>Sample analysis time<\/strong><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Ca\u00b2\u207a: Not available<\/td>\n<td>35 seconds<\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4 data-start=\"1062\" data-end=\"1080\"><strong data-start=\"1067\" data-end=\"1080\">Cartridge<\/strong><\/h4>\n<div class=\"_tableContainer_1rjym_1\">\n<div class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\">\n<table>\n<thead>\n<tr>\n<th><strong>Test panel options<\/strong><\/th>\n<th><strong>Test volume options<\/strong><\/th>\n<th><strong>Storage conditions<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u2022 i-Smart 30 PRO Cartridge E4<\/p>\n<p>Na\u207a, K\u207a, Cl\u207b, Ca\u00b2\u207a<\/p>\n<p>\u2022 i-Smart 30 PRO Cartridge<\/p>\n<p>Na\u207a, K\u207a, Cl\u207b<\/td>\n<td>50 tests \/ 4 weeks<\/p>\n<p>100 tests \/ 4 weeks<\/p>\n<p>200 tests \/ 4 weeks<\/p>\n<p>300 tests \/ 4 weeks<\/td>\n<td>10\u201330 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td><strong>Components<\/strong><\/td>\n<td><strong>Dimensions<\/strong><\/td>\n<td><strong>Weight<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u2022 Micro-sensor board<\/p>\n<p>\u2022 Cal1, Cal2<\/p>\n<p>\u2022 Reference solution<\/p>\n<p>\u2022 Sampler and waste bag<\/p>\n<p>\u2022 Valve and piping<\/td>\n<td>138(W) \u00d7 139(H) \u00d7 80(D) mm<\/td>\n<td>0.8 kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h3 data-start=\"69\" data-end=\"108\"><strong data-start=\"73\" data-end=\"108\">The i-Smart 30 pro Electrolyte Analyzer <\/strong><\/h3>\n<h3 data-start=\"69\" data-end=\"108\"><strong data-start=\"73\" data-end=\"108\">1 \u2013 Maintenance-free cartridge<\/strong><\/h3>\n<ul data-start=\"109\" data-end=\"396\">\n<li data-start=\"109\" data-end=\"180\">\n<p data-start=\"111\" data-end=\"180\">The all-in-one cartridge contains all reagents and consumables.<\/p>\n<\/li>\n<li data-start=\"181\" data-end=\"248\">\n<p data-start=\"183\" data-end=\"248\">The only maintenance required is replacing the cartridge.<\/p>\n<\/li>\n<li data-start=\"249\" data-end=\"396\">\n<p data-start=\"251\" data-end=\"396\">Reduces expenses and increases profitability.<br data-start=\"298\" data-end=\"301\" \/><em data-start=\"301\" data-end=\"394\">Available to obtain the results of 4 parameters (Na\u207a, K\u207a, Cl\u207b, Ca\u00b2\u207a) in a single test.<\/em><\/p>\n<\/li>\n<\/ul>\n<p data-start=\"398\" data-end=\"572\"><strong data-start=\"398\" data-end=\"435\">Types of cartridges available:<\/strong><br data-start=\"435\" data-end=\"438\" \/>\u2611 50 samples \/ 4 weeks<br data-start=\"468\" data-end=\"471\" \/>\u2611 100 samples \/ 4 weeks<br data-start=\"502\" data-end=\"505\" \/>\u2611 200 samples \/ 4 weeks<br data-start=\"536\" data-end=\"539\" \/>\u2611 300 samples \/ 4 weeks<\/p>\n<h3 data-start=\"579\" data-end=\"634\"><strong data-start=\"583\" data-end=\"634\">2 \u2013 Reliable QC management with the LJ graph<\/strong><\/h3>\n<ul data-start=\"635\" data-end=\"837\">\n<li data-start=\"635\" data-end=\"720\">\n<p data-start=\"637\" data-end=\"720\">Easy performance verification thanks to the i-Smart electrolyte QC (3 levels).<\/p>\n<\/li>\n<li data-start=\"721\" data-end=\"837\">\n<p data-start=\"723\" data-end=\"837\">Simplified quality control management and improved results tracking via the Levey-Jennings (LJ) chart.<\/p>\n<\/li>\n<\/ul>\n<h3 data-start=\"844\" data-end=\"893\"><strong data-start=\"848\" data-end=\"893\">3 \u2013 Practical urine test without dilution<\/strong><\/h3>\n<ul data-start=\"894\" data-end=\"1088\">\n<li data-start=\"894\" data-end=\"999\">\n<p data-start=\"896\" data-end=\"999\">The wide detection range of the K\u207a sensor allows for the analysis of urine samples without dilution.<\/p>\n<\/li>\n<li data-start=\"1000\" data-end=\"1088\">\n<p data-start=\"1002\" data-end=\"1088\">The absence of pretreatment reduces testing steps and handling errors.<\/p>\n<\/li>\n<\/ul>\n<h3 data-start=\"85\" data-end=\"113\"><strong data-start=\"89\" data-end=\"113\">4. Easy to use<\/strong><\/h3>\n<ul data-start=\"114\" data-end=\"245\">\n<li data-start=\"114\" data-end=\"171\">\n<p data-start=\"116\" data-end=\"171\">Simple usage steps and user-friendly interface.<\/p>\n<\/li>\n<li data-start=\"172\" data-end=\"245\">\n<p data-start=\"174\" data-end=\"245\">Easy configuration of the network interface to LIS\/HIS systems.<\/p>\n<\/li>\n<\/ul>\n<h3 data-start=\"252\" data-end=\"308\"><strong data-start=\"256\" data-end=\"308\">5. High-performance hardware with intelligent software<\/strong><\/h3>\n<ul data-start=\"309\" data-end=\"568\">\n<li data-start=\"309\" data-end=\"432\">\n<p data-start=\"311\" data-end=\"432\">Offers improved performance stability thanks to an enhanced processor and the Windows\u00ae 10 operating system.<\/p>\n<\/li>\n<li data-start=\"433\" data-end=\"473\">\n<p data-start=\"435\" data-end=\"473\">Equipped with ample memory space.<\/p>\n<\/li>\n<li data-start=\"474\" data-end=\"568\">\n<p data-start=\"476\" data-end=\"568\">Improved usability thanks to an intuitive graphical user interface (GUI) and touchscreen.<\/p>\n<\/li>\n<\/ul>\n<h3 data-start=\"575\" data-end=\"613\"><strong data-start=\"579\" data-end=\"613\">6 Battery operation<\/strong><\/h3>\n<ul data-start=\"614\" data-end=\"722\">\n<li data-start=\"614\" data-end=\"673\">\n<p data-start=\"616\" data-end=\"673\">Operates on battery for up to 2 hours.<\/p>\n<\/li>\n<li data-start=\"674\" data-end=\"722\">\n<p data-start=\"676\" data-end=\"722\">Can operate in the event of a power outage.<\/p>\n<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p><strong data-start=\"72\" data-end=\"109\">The i-Smart 30 pro Electrolyte Analyzer<\/strong> It features a 7-inch color touchscreen and easy-to-use software. Its all-in-one cartridge system integrates electrodes, reagents, and all necessary consumables.<\/p>\n<ul>\n<li data-start=\"39\" data-end=\"123\">\n<p data-start=\"41\" data-end=\"123\">Measures Na\u207a, K\u207a, Cl\u207b and Ca\u00b2\u207a concentrations with 60 \u00b5L of blood or urine.<\/p>\n<\/li>\n<li data-start=\"124\" data-end=\"174\">\n<p data-start=\"126\" data-end=\"174\">Provides patient results in 35 seconds.<\/p>\n<\/li>\n<li data-start=\"175\" data-end=\"225\">\n<p data-start=\"177\" data-end=\"225\">Maintenance-free and easy-to-use cartridge.<\/p>\n<\/li>\n<li data-start=\"226\" data-end=\"282\">\n<p data-start=\"228\" data-end=\"282\">Improved hardware ensuring stable performance.<\/p>\n<\/li>\n<li data-start=\"283\" data-end=\"341\">\n<p data-start=\"285\" data-end=\"341\">Reliable quality control management with LJ graph.<\/p>\n<\/li>\n<li data-start=\"342\" data-end=\"422\" data-is-last-node=\"\">\n<p data-start=\"344\" data-end=\"422\" data-is-last-node=\"\">Operates on battery power for up to two hours without being plugged in.<\/p>\n<\/li>\n<\/ul>","protected":false},"featured_media":473,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[36],"product_tag":[],"class_list":["post-354","product","type-product","status-publish","has-post-thumbnail","product_cat-analyseur-des-electrolytes","first","instock","virtual","product-type-simple"],"_links":{"self":[{"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product\/354","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/comments?post=354"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/media\/473"}],"wp:attachment":[{"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/media?parent=354"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product_brand?post=354"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product_cat?post=354"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product_tag?post=354"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}