{"id":642,"date":"2025-10-16T13:36:52","date_gmt":"2025-10-16T13:36:52","guid":{"rendered":"https:\/\/megadiagnostic.com\/?post_type=product&#038;p=642"},"modified":"2026-01-22T14:51:09","modified_gmt":"2026-01-22T14:51:09","slug":"dm1424","status":"publish","type":"product","link":"https:\/\/megadiagnostic.com\/en\/product\/dm1424\/","title":{"rendered":"DM1424 High-Speed Centrifuge - DLAB"},"content":{"rendered":"<h3 data-start=\"911\" data-end=\"1303\"><span data-start=\"914\" data-end=\"952\">C<\/span><strong data-start=\"914\" data-end=\"952\">DM1424 high-speed centrifuge<\/strong><\/h3>\n<p data-start=\"911\" data-end=\"1303\">is a compact and efficient piece of equipment, specially designed for the <strong data-start=\"1021\" data-end=\"1087\">rapid separation of small volumes of biological samples<\/strong>. It is particularly suited to the <strong data-start=\"1130\" data-end=\"1170\">hematocrit (HTC) determination<\/strong>, there <strong data-start=\"1175\" data-end=\"1208\">separation of micro-solutions<\/strong>, as well as to <strong data-start=\"1225\" data-end=\"1300\">applications in biochemistry, immunology, genetics and clinical research<\/strong>.<\/p>\n<p><strong data-start=\"1317\" data-end=\"1345\">Main applications<\/strong><\/p>\n<ul>\n<li data-start=\"1346\" data-end=\"1409\">\n<p data-start=\"1348\" data-end=\"1409\">Determination of <strong data-start=\"1366\" data-end=\"1394\">erythrocyte fractions<\/strong> in the blood<\/p>\n<\/li>\n<li data-start=\"1410\" data-end=\"1488\">\n<p data-start=\"1412\" data-end=\"1488\"><strong data-start=\"1412\" data-end=\"1445\">Hematocrit (HTC) measurement<\/strong> for clinical and doping analyses<\/p>\n<\/li>\n<li data-start=\"1489\" data-end=\"1552\">\n<p data-start=\"1491\" data-end=\"1552\"><strong data-start=\"1491\" data-end=\"1520\">DNA and RNA separation<\/strong> for molecular research<\/p>\n<\/li>\n<li data-start=\"1553\" data-end=\"1652\">\n<p data-start=\"1555\" data-end=\"1652\"><strong data-start=\"1555\" data-end=\"1603\">Photometric determination of bilirubin<\/strong> in the blood samples of newborns<\/p>\n<\/li>\n<li data-start=\"1653\" data-end=\"1708\">\n<p data-start=\"1655\" data-end=\"1708\"><strong data-start=\"1655\" data-end=\"1677\">Vitamin tests<\/strong> And <strong data-start=\"1681\" data-end=\"1706\">veterinary analyses<\/strong><\/p>\n<\/li>\n<li data-start=\"1709\" data-end=\"1763\">\n<p data-start=\"1711\" data-end=\"1763\"><strong data-start=\"1711\" data-end=\"1733\">Biochemical tests<\/strong> And <strong data-start=\"1737\" data-end=\"1761\">routine clinics<\/strong><\/p>\n<\/li>\n<\/ul>\n<h3 data-start=\"1770\" data-end=\"1808\">\u2699\ufe0f <strong data-start=\"1777\" data-end=\"1808\">Technical specifications<\/strong><\/h3>\n<div class=\"_tableContainer_1rjym_1\">\n<div class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1809\" data-end=\"2481\">\n<thead data-start=\"1809\" data-end=\"1844\">\n<tr data-start=\"1809\" data-end=\"1844\">\n<th data-start=\"1809\" data-end=\"1830\" data-col-size=\"sm\"><strong data-start=\"1811\" data-end=\"1829\">Specifications<\/strong><\/th>\n<th data-start=\"1830\" data-end=\"1844\" data-col-size=\"md\"><strong data-start=\"1832\" data-end=\"1842\">DM1424<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"1881\" data-end=\"2481\">\n<tr data-start=\"1881\" data-end=\"1915\">\n<td data-start=\"1881\" data-end=\"1895\" data-col-size=\"sm\"><strong data-start=\"1883\" data-end=\"1894\">Speed<\/strong><\/td>\n<td data-start=\"1895\" data-end=\"1915\" data-col-size=\"md\">200 to 12,000 rpm<\/td>\n<\/tr>\n<tr data-start=\"1916\" data-end=\"1945\">\n<td data-start=\"1916\" data-end=\"1931\" data-col-size=\"sm\"><strong data-start=\"1918\" data-end=\"1930\">RCF max.<\/strong><\/td>\n<td data-start=\"1931\" data-end=\"1945\" data-col-size=\"md\">13,680 \u00d7 g<\/td>\n<\/tr>\n<tr data-start=\"1946\" data-end=\"1984\">\n<td data-start=\"1946\" data-end=\"1973\" data-col-size=\"sm\"><strong data-start=\"1948\" data-end=\"1972\">Speed accuracy<\/strong><\/td>\n<td data-start=\"1973\" data-end=\"1984\" data-col-size=\"md\">\u00b120 rpm<\/td>\n<\/tr>\n<tr data-start=\"1985\" data-end=\"2033\">\n<td data-start=\"1985\" data-end=\"2009\" data-col-size=\"sm\"><strong data-start=\"1987\" data-end=\"2008\">Rotor capacity<\/strong><\/td>\n<td data-start=\"2009\" data-end=\"2033\" data-col-size=\"md\">24 capillary tubes<\/td>\n<\/tr>\n<tr data-start=\"2034\" data-end=\"2079\">\n<td data-start=\"2034\" data-end=\"2047\" data-col-size=\"sm\"><strong data-start=\"2036\" data-end=\"2046\">Engine<\/strong><\/td>\n<td data-start=\"2047\" data-end=\"2079\" data-col-size=\"md\">DC Brushless, maintenance-free<\/td>\n<\/tr>\n<tr data-start=\"2080\" data-end=\"2133\">\n<td data-start=\"2080\" data-end=\"2118\" data-col-size=\"sm\"><strong data-start=\"2082\" data-end=\"2117\">Acceleration\/braking time<\/strong><\/td>\n<td data-start=\"2118\" data-end=\"2133\" data-col-size=\"md\">30 s \/ 30 s<\/td>\n<\/tr>\n<tr data-start=\"2134\" data-end=\"2192\">\n<td data-start=\"2134\" data-end=\"2149\" data-col-size=\"sm\"><strong data-start=\"2136\" data-end=\"2148\">Timer<\/strong><\/td>\n<td data-start=\"2149\" data-end=\"2192\" data-col-size=\"md\">30 seconds to 99 minutes or continuous operation<\/td>\n<\/tr>\n<tr data-start=\"2193\" data-end=\"2226\">\n<td data-start=\"2193\" data-end=\"2219\" data-col-size=\"sm\"><strong data-start=\"2195\" data-end=\"2218\">Rapid mode (PULSE)<\/strong><\/td>\n<td data-start=\"2219\" data-end=\"2226\" data-col-size=\"md\">Yes<\/td>\n<\/tr>\n<tr data-start=\"2227\" data-end=\"2265\">\n<td data-start=\"2227\" data-end=\"2243\" data-col-size=\"sm\"><strong data-start=\"2229\" data-end=\"2242\">Display<\/strong><\/td>\n<td data-start=\"2243\" data-end=\"2265\" data-col-size=\"md\">Intuitive LCD screen<\/td>\n<\/tr>\n<tr data-start=\"2266\" data-end=\"2352\">\n<td data-start=\"2266\" data-end=\"2281\" data-col-size=\"sm\"><strong data-start=\"2268\" data-end=\"2280\">Security<\/strong><\/td>\n<td data-start=\"2281\" data-end=\"2352\" data-col-size=\"md\">Lid locking, overspeed and overheat detection<\/td>\n<\/tr>\n<tr data-start=\"2353\" data-end=\"2389\">\n<td data-start=\"2353\" data-end=\"2382\" data-col-size=\"sm\"><strong data-start=\"2355\" data-end=\"2381\">Automatic diagnostics<\/strong><\/td>\n<td data-start=\"2382\" data-end=\"2389\" data-col-size=\"md\">Yes<\/td>\n<\/tr>\n<tr data-start=\"2390\" data-end=\"2437\">\n<td data-start=\"2390\" data-end=\"2415\" data-col-size=\"sm\"><strong data-start=\"2392\" data-end=\"2414\">Dimensions (L\u00d7W\u00d7H)<\/strong><\/td>\n<td data-start=\"2415\" data-end=\"2437\" data-col-size=\"md\">364 \u00d7 280 \u00d7 274 mm<\/td>\n<\/tr>\n<tr data-start=\"2438\" data-end=\"2481\">\n<td data-start=\"2438\" data-end=\"2457\" data-col-size=\"sm\"><strong data-start=\"2440\" data-end=\"2456\">Food<\/strong><\/td>\n<td data-start=\"2457\" data-end=\"2481\" data-col-size=\"md\">200\u2013240 V \/ 50\u201360 Hz<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h3 data-start=\"2488\" data-end=\"2535\"><strong data-start=\"2495\" data-end=\"2535\">Performance and ease of use<\/strong><\/h3>\n<ul data-start=\"2536\" data-end=\"2913\">\n<li data-start=\"2536\" data-end=\"2600\">\n<p data-start=\"2538\" data-end=\"2600\"><strong data-start=\"2538\" data-end=\"2572\">Independent and precise control<\/strong> speed and time<\/p>\n<\/li>\n<li data-start=\"2601\" data-end=\"2673\">\n<p data-start=\"2603\" data-end=\"2673\"><strong data-start=\"2603\" data-end=\"2626\">Intuitive interface<\/strong> with <strong data-start=\"2632\" data-end=\"2671\">clear LCD screen and simplified menus<\/strong><\/p>\n<\/li>\n<li data-start=\"2674\" data-end=\"2739\">\n<p data-start=\"2676\" data-end=\"2739\"><strong data-start=\"2676\" data-end=\"2705\">9 memorable programs<\/strong> for recurring procedures<\/p>\n<\/li>\n<li data-start=\"2740\" data-end=\"2795\">\n<p data-start=\"2742\" data-end=\"2795\"><strong data-start=\"2742\" data-end=\"2760\">PULSE function<\/strong> for rapid centrifugations<\/p>\n<\/li>\n<li data-start=\"2796\" data-end=\"2858\">\n<p data-start=\"2798\" data-end=\"2858\"><strong data-start=\"2798\" data-end=\"2837\">Automatic speed\/RCF switching<\/strong> according to the protocol<\/p>\n<\/li>\n<li data-start=\"2859\" data-end=\"2913\">\n<p data-start=\"2861\" data-end=\"2913\"><strong data-start=\"2861\" data-end=\"2897\">Rapid acceleration and braking<\/strong> (30 seconds each)<\/p>\n<\/li>\n<\/ul>\n<h3 data-start=\"2920\" data-end=\"2952\"><strong data-start=\"2927\" data-end=\"2952\">Safety and reliability<\/strong><\/h3>\n<ul data-start=\"2953\" data-end=\"3188\">\n<li data-start=\"2953\" data-end=\"2998\">\n<p data-start=\"2955\" data-end=\"2998\"><strong data-start=\"2955\" data-end=\"2996\">Automatic lid locking<\/strong><\/p>\n<\/li>\n<li data-start=\"2999\" data-end=\"3047\">\n<p data-start=\"3001\" data-end=\"3047\"><strong data-start=\"3001\" data-end=\"3045\">Overspeed and overheating detector<\/strong><\/p>\n<\/li>\n<li data-start=\"3048\" data-end=\"3086\">\n<p data-start=\"3050\" data-end=\"3086\"><strong data-start=\"3050\" data-end=\"3084\">Automatic internal diagnostics<\/strong><\/p>\n<\/li>\n<li data-start=\"3087\" data-end=\"3150\">\n<p data-start=\"3089\" data-end=\"3150\"><strong data-start=\"3089\" data-end=\"3123\">Automatic rotor detection<\/strong> for increased security<\/p>\n<\/li>\n<li data-start=\"3151\" data-end=\"3188\">\n<p data-start=\"3153\" data-end=\"3188\"><strong data-start=\"3153\" data-end=\"3170\">Audible alert<\/strong> at the end of the cycle<\/p>\n<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p data-start=\"271\" data-end=\"848\">There <strong data-start=\"274\" data-end=\"312\">DM1424 high-speed centrifuge<\/strong> is designed for the <strong data-start=\"332\" data-end=\"378\">determination of erythrocyte fractions<\/strong> and the <strong data-start=\"385\" data-end=\"418\">separation of micro-solutions<\/strong> in clinical, veterinary, research, and molecular biology laboratories. With a <strong data-start=\"516\" data-end=\"577\">Adjustable speed from 200 to 12,000 rpm (up to 13,680 \u00d7 g)<\/strong>, A <strong data-start=\"582\" data-end=\"628\">aluminum rotor with 24 capillary tubes<\/strong> and one <strong data-start=\"635\" data-end=\"670\">maintenance-free brushless motor<\/strong>, she guarantees <strong data-start=\"686\" data-end=\"721\">precision, speed and safety<\/strong>. Ideal for hematocrit analysis, neonatal bilirubin, DNA\/RNA extraction and specialized clinical tests.<\/p>","protected":false},"featured_media":643,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[57],"product_cat":[56],"product_tag":[],"class_list":["post-642","product","type-product","status-publish","has-post-thumbnail","product_brand-dlab","product_cat-petit-materiel-de-laboratoire","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product\/642","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/comments?post=642"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/media\/643"}],"wp:attachment":[{"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/media?parent=642"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product_brand?post=642"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product_cat?post=642"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/megadiagnostic.com\/en\/wp-json\/wp\/v2\/product_tag?post=642"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}